Part Details for TLE4998P4 by Infineon Technologies AG
Results Overview of TLE4998P4 by Infineon Technologies AG
- Distributor Offerings: (1 listing)
- Number of FFF Equivalents: (0 replacements)
- CAD Models: (Request Part)
- Number of Functional Equivalents: (0 options)
- Part Data Attributes: (Available)
- Reference Designs: (Not Available)
Tip: Data for a part may vary between manufacturers. You can filter for manufacturers on the top of the page next to the part image and part number.
TLE4998P4 Information
TLE4998P4 by Infineon Technologies AG is a Magnetic Field Sensor.
Magnetic Field Sensors are under the broader part category of Sensors/Transducers.
Sensors and transducers detect and measure physical quantities like temperature, pressure, and force, converting them into electrical signals for various applications. Read more about Sensors/Transducers on our Sensors/Transducers part category page.
Price & Stock for TLE4998P4
Part # | Distributor | Description | Stock | Price | Buy | |
---|---|---|---|---|---|---|
DISTI #
726-TLE4998P4
|
Mouser Electronics | Board Mount Hall Effect / Magnetic Sensors HALL SENSOR 4.5-5.5V PWM OPEN DRAIN RoHS: Compliant | 0 |
|
$2.1500 | Order Now |
Part Details for TLE4998P4
TLE4998P4 CAD Models
TLE4998P4 Part Data Attributes
|
TLE4998P4
Infineon Technologies AG
Buy Now
Datasheet
|
Compare Parts:
TLE4998P4
Infineon Technologies AG
Hall Effect Sensor, 50mT Min, 200mT Max, 0.30-0.60V, BICMOS, Plastic/Epoxy, Rectangular, 4 Pin, Through Hole Mount, GREEN PACKAGE-4
Select a part to compare: |
Pbfree Code | Yes | |
Rohs Code | Yes | |
Part Life Cycle Code | Active | |
Ihs Manufacturer | INFINEON TECHNOLOGIES AG | |
Package Description | GREEN PACKAGE-4 | |
Reach Compliance Code | compliant | |
ECCN Code | EAR99 | |
HTS Code | 8542.39.00.01 | |
Factory Lead Time | 4 Weeks | |
Samacsys Manufacturer | Infineon | |
Additional Feature | OPEN DRAIN OUTPUT, REVERSE POLARITY PROTECTION, SHORT CIRCUIT PROTECTION | |
Body Breadth | 1 mm | |
Body Height | 3.71 mm | |
Body Length or Diameter | 5.34 mm | |
Housing | PLASTIC | |
Magnetic Field Range-Max | 200 mT | |
Magnetic Field Range-Min | 50 mT | |
Mounting Feature | THROUGH HOLE MOUNT | |
Number of Terminals | 4 | |
Operating Current-Max | 8 mA | |
Operating Temperature-Max | 150 °C | |
Operating Temperature-Min | -40 °C | |
Output | SINGLE-ENDED | |
Output Circuit Type | SINGLE-ENDED | |
Output Current-Max | 5 mA | |
Output Interface Type | 2-WIRE INTERFACE | |
Output Type | ANALOG CURRENT | |
Package Body Material | PLASTIC/EPOXY | |
Package Equivalence Code | SIP4,.03,50 | |
Package Shape/Style | RECTANGULAR | |
Resistance | 1000 Ω | |
Sensors/Transducers Type | MAGNETIC FIELD SENSOR,HALL EFFECT | |
Supply Voltage-Max | 5 V | |
Supply Voltage-Min | 4.1 V | |
Surface Mount | NO | |
Technology | BICMOS | |
Termination Type | SOLDER |
TLE4998P4 Frequently Asked Questions (FAQ)
-
A 4-layer PCB with a solid ground plane and a separate power plane is recommended. Keep the analog and digital grounds separate and connect them at a single point. Use short and wide traces for the power supply lines and keep the sensitive analog signals away from the digital signals.
-
The TLE4998P4 has an internal calibration mechanism. However, for optimal accuracy, it is recommended to perform an external calibration using an external reference voltage and a calibration resistor. Refer to the application note for the calibration procedure.
-
The TLE4998P4 can operate from -40°C to 150°C. However, the accuracy and performance may degrade at extreme temperatures. It is recommended to operate the device within the recommended temperature range of -20°C to 125°C for optimal performance.
-
Yes, the TLE4998P4 has built-in noise filtering and is designed to operate in noisy environments. However, it is recommended to take additional noise reduction measures such as using a noise filter capacitor and shielding the device from electromagnetic interference.
-
Start by checking the power supply voltage and ensuring that it is within the recommended range. Check the device's output voltage and current consumption. Use an oscilloscope to check for any noise or oscillations on the output. Refer to the datasheet and application notes for troubleshooting guidelines.